Skip to main content

Bend- & edge protector for Heating cable incl. 4 cable ties

This edge protector for attaching to heating & frost protection cables protects the cable from sharp edges, e.g. at the transition from gutter to downpipe. The edge protector made of high-quality stainless steel also serves as a kink protector. Too small bending radii, which can damage the heating cable, are effectively prevented with this practical utensil.

At a glance:

  • Guides the heating cable safely over sharp edges
  • Prevents kinking of the heating cable
  • Ideal for the transition from gutter to downpipe
  • Kink protection made of high-quality stainless steel
  • Includes 4 cable ties for easy installation
  • Suitable for heating cable item no. 26592

Scope of delivery:

1x Edge & kink protection for Heating cable incl. 4 cable ties

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Kerbl combines over 50 years of experience with cutting-edge innovation to offer you high-quality and reliable agricultural products. Whether animal accessories, equestrian and pet supplies or solutions for stables and farms - Kerbl's comprehensive range covers every need. The brand stands for functionality and durability and helps you make your everyday life more efficient. Benefit from tailor-made solutions that impress with expertise and advanced technology.

    Choose accessories

    Kerbl Frost protection heating cable for gutters and pipes
    Kerbl Frost protection heating cable for gutters and pipes
    Frost protection heating cable for gutters and pipes The plug-in frost protection heating cable keeps gutters and pipes free of frost. The plug-in heating cable developed for gutter and piping fulfills the requirements for strength class M2 according to IEC60800: 2009 in order to keep gutters and piping safely frost-free. Thanks to the high heating output of 20 watts per meter, the heating cable keeps gutters, downpipes and pipes free of frost even at very low temperatures. The integrated temperature switch reliably switches the heating cable on at a temperature of +3 ° C and off again at +12 ° C. Overview of antifreeze heating cables for gutters and pipes: Suitable for gutters: strength class M2 Plug-in heating cable for easy installation Integrated thermostat for energy-saving use High protection class: IPX7 Suitable for metal water pipes Incl. Earthing contact plug for high security Length of connecting cable: 2 m IPX7 Protection class: I Note: Please note that each heating cable connection must be protected by a separate FI circuit breaker. (e.g. Art. No. 27598, pluggable personal protection switch) The heating cable is in front of sharp edges, e.g. Protect at the transition from gutter to downpipe using edge protection (Art. No. 27597). The heating cable must never touch, overlap or cross another heating cable. In order to rule out contact permanently, the use of suitable spacers is recommended (Art. No. 27596). Pipes, metal gutters, protective pipes and metal sheaths must be earthed before laying for safety reasons. Diameter: 6 mm Sizes: Watt (length) 100 W (5 m) 200 W (10 m) 300 W (15 m) 400 W (20 m) 500 W (25 m) 800 W (40 m) 1000 W (50 m) Content: 1 anti-freeze heating cable for gutters and pipes

    From €52.99*
    5x Spacer for Heating cable incl. 10 cable ties
    5x Spacer for Heating cable incl. 10 cable ties
    5x Spacer for Heating cable incl. 10 cable ties The heating cable must not touch, cross or overlap itself or another heating cable at any point. To permanently prevent contact, these 5 spacers are ideal. The spacers ensure that the heating cable is guided safely without any points of contact. The spacers are very easy to mount with the 10 cable ties. Thanks to the holes in the spacers, the heating cable is fixed and cannot slip. At a glance: Guarantees secure guidance of the heating cable Prevents the heating cable from touching For heating cables, frost protection cables of all kinds (like item no. 26592) 10 Pieces of cable ties enable easy mounting Scope of delivery: 5x Spacer for Heating cable incl. 10 cable ties

    €4.49*
    Personal safety switch RCD BDI-A 2 30
    Personal safety switch RCD BDI-A 2 30
    Personal protection switch RCD switch BDI-A 2 30 The BDI-A 2 30 Personal protection adapter (also called RCD) is used to protect against dangerous electric shocks. Thanks to the residual-current circuit breaker, faulty currents are detected immediately and disconnected from the mains at lightning speed. Life-threatening electrical accidents, e.g. caused by direct or indirect contact with live equipment, are effectively prevented with the personal protection plug. The circuit breaker with hinged cover is equipped with protection class IP54, which means that it is dust-proof and splash-proof and ideally suited for outdoor use. At a glance: Disconnects the active conductors from the mains as soon as residual currents occur Provides protection against life-threatening electric shocks Reliable personal protection with 30 mA rated residual current Residual current circuit-breaker with double-pole disconnection Suitable for outdoor use thanks to protection class IP54 Personal protection plug with hinged cover, thus protected against dust and splash water Suitable for heating cable item no. 26592 With child protection Technical data: Nominal frequency: 50 Hz - 60 Hz Max. switching capacity: 3.500 W Max. Current carrying capacity: 16 A Max. Ambient temperature: 40 °C Min. Ambient temperature: -25 °C Area of application: Outdoor Protection class: IP54 Scope of delivery: 1x RCD Personal protection switch BDI-A 2 30

    €42.99*